原表转录或建议式:M_H = P_el*t/(33.3*eta_FC)。; P:W; t:h; 33.3Wh/g -> M:g Constant-power/efficiency preliminary sizing before boil-off/unused reserve
LaTeX 源码
M_H=\frac{P_{\mathrm{el}}t}{33.3\,\eta_{FC}}推导与代入
- Energy-to-fuel unit audit; add loss/reserve consistently
- 原文称33.3Wh/g electrical energy content,物理上是H2 LHV;电输出还要eta。
来源与复核
- 原表与全部字段
- 仓库文件 · mission-equations.csv 项目仓库 · 需访问权限