\begin{aligned}\frac{dm}{dt}&=-\dot m_{FC}-\dot m_{vent},\qquad U=mu,\\\frac{dU}{dt}&=\dot Q_{leak}+\dot Q_{tank,rec}+\dot Q_{heater}-(\dot m_{FC}+\dot m_{vent})h_{out}.\end{aligned}