定稿含 18 行、5 列。列名为parameter_id、value、unit、identity_or_assumption、source_or_definition。
表中数据
| parameter_id | value | unit | identity_or_assumption | source_or_definition |
|---|---|---|---|---|
| target_T | 298.15 | K | research target: inherited 25degC ambient, NOT an OEM measured inlet requirement | report-data.Mission.selected.input_settings.ambient_T_K |
| inlet_gauge_pressure | 0.9 | bar(g) | IE manual nominal, inherited frozen R2 input; pressure-drop qualification pending | r2-integration.json fuel_supply.IE_inlet_pressure_gauge_bar.nominal |
| ambient_pressure | 101325 | Pa | inherited reference atmosphere | report-data selected input_settings.base_pressure_Pa |
| bar_to_Pa | 100000 | Pa/bar | P105 | SI unit definition |
| target_absolute_pressure | 191325 | Pa | derived ambient plus nominal gauge pressure | Pambient+Pgauge*bar_to_Pa |
| target_density | 0.16 | kg/m3 | native normal-H2 EOS result, not an independent measurement | fzero(pEOS(Ttarget,rho)-Ptarget) |
| target_enthalpy | 3932193.65 | J/kg | native normal-H2 EOS result, same energy reference as tank | r23.eos; Leachman2009 |
| FC_net_efficiency | 0.5 | 1 | inherited net electrical efficiency scenario | report-data selected input_settings.eta_fc_bus |
| H2_LHV | 120000000 | J/kg | inherited lower heating value | report-data selected input_settings.LHV_J_kg |
| tank_recovery_cap | 50 | W | original tank-pressure support branch only, not external HX capacity | all-engineering-parameters.csv CRYO.recovery_cap |
| tank_recovery_fraction_cap | 0.05 | 1 | original cap relative to chemical-minus-net-power upper bound | all-engineering-parameters.csv CRYO.recovery_fraction |
| C05_HX_budget | 0.3 | kg | hardware mass budget only; no UA/thermal-capacity evidence | frozen CRYO-BUDGET-1.2.0 vessel.warming_HX_budget_kg |
| startup_purge_H2 | 1.00e-3 | kg | conditional 1g heating illustration; purge need not all pass through stack | report-data selected input_settings.startup_vent_H2_kg |
| startup_duration | 60 | s | original startup interval, no startup thermal-inertia model | report-data selected input_settings.startup_s |
| seconds_per_hour | 3600 | s/h | P105 | unit definition |
| target_density_root_TolX | 1.00e-12 | kg/m3 | numerical root setting, not physical accuracy | supplement code |
| prestate_pressure_check_tolerance | 0.1 | Pa | CSV round-trip/state-alignment check only | supplement code |
| integral_closure_relative_tolerance | 1.00e-10 | 1 | postprocessing integration check only | supplement code |
下载
来源与复核